Page 2 - BR100 Product Selection Guide
P. 2
Product Index and Application Guide
Paint
Application Features 1 Performance
Systems
Dura Tech ™ 5000/Mx (PVDF) Dura Tech ™ nt (SMP) Minimum Slope X:12 Spanning Capability Uplift (ASTM E1592) Air/Water Infiltration (ASTM) UL 2218 Impact (Hail) Code Compliance Report 4 Manufacturing Location
Liner Panel Coverage (in) Standard Gauges Height (in) Weathertightness 2 Tapered Attachment UL790 Fire - Roof UL263 Fire - Wall UL580 Uplift FM Listed
Roof Wall Soffit Curved 3
Page CONCEALED FASTENER PANELS
Design Span hp ● ○ ● 12, 16, 17, 18 22, 24 1 ⁄4 3 2 G VG CL ● ● ● ● ● ● ● F,T
1
Design Span hp ● ○ ● 12, 16, 17, 18 3 2 G VG CL ● ● ● ● ● ● F,T
Wide Batten 22, 24 1 ⁄4
Span-Lok hp ● ○ ● 12,16 22, 24 2 1 ⁄4 VG E CL ● ● ● ● ● ● ● ● F,T
2 Curved ● ● 16 22 2 1 ⁄4 VG E M CL ● ● ● ● ● ● F,T
Span-Lok
SpanSeam ● ○ ● 16 22, 24 2 1 ⁄4 VG E CL ● ● ● ● ● ● ● F,T
Select Seam 1
Narrow Batten ● ○ ● 12, 16, 21 ⁄4 22, 24 1 3 N/A G M ● CL ● ● ● ● ● ● ● F,T
3
Select Seam ● ○ ● 1 1 1 7 3 N/A N/A ● CL ● ● ● ● ● ● F,T
Wide Batten 13 ⁄4, 17 ⁄4, 22 ⁄2 22, 24 1 ⁄8
4 Klip-Rib ● ○ ● ● 16 22-26 1 ⁄8 1 E VG CR CL ● ● ● ● ● ● ● T
5
5 Prestige Series ● ● ● 12 20-24 1 ⁄2 N/A G G CL, D ● ● N/A ● N/A N/A ● F,T
1
6 Flush Panel ● ● ● ● 12 22, 24 7 ⁄8 N/A G G D ● ● N/A ● N/A N/A T
1
7 Flex Series ● ● 12 20-24 1 ⁄4 N/A G G CL, D ● ● N/A ● N/A N/A A,F
1
1 ⁄2
8 TW-12 ● ● 12 20-24 7 ⁄8 N/A G G CL, D ● ● N/A ● N/A N/A A,F
Perception
9 Collection ● ● 12 20-24 7 ⁄8 N/A G G CL, D ● ● N/A ● N/A N/A A,F
Page EXPOSED FASTENER PANELS
HR-36 ● ● ● ● 36 20-29 1 ⁄2 1 VG VG CR D C ● ● ● ● F,T
1
10
Reversed ● ● ● 36 20-29 1 ⁄2 N/A VG VG CR D C ● N/A ● N/A N/A F,T
1
HR-36
Box Rib ● ● ● 36 20-29 1 ⁄2 N/A VG VG CR D C ● N/A ● N/A N/A F
1
11
Reversed ● ● ● ● 36 20-29 1 1 VG VG CR D C ● ● F
Box Rib 1 ⁄2
M
32 (ROOF)
Nu-Wave
12 Corrugated ● ● ● ● 34 ⁄3 (WALL) 20-26 7 ⁄8 3 G G CR D C ● ● ● ● F,T
2
Mini-V-Beam ● ● ● ● 32 20-26 1 ⁄8 2 E VG D C ● ● ● ● T
3
13 Reversed
3
Mini-V-Beam ● ● ● ● 32 20-26 1 ⁄8 2 E VG D C ● T
Super-Span ● ● ● ● 36 22-26 1 ⁄4 1 1 G G CR D C ● ● ● ● F,T
Reversed
14 Super-Span ● ● ● ● 36 22-26 1 ⁄4 N/A G G D C N/A ● N/A N/A F,T
1
PBR ● ● ● 36 26 1 ⁄4 1 1 G G D C ● ● Sa,
Sp
U-Panel ● ● ● ● ● 36 20-29 3 ⁄4 3 G G D C ● ● ● F
15
X-Span ● ● ● 36 26,29 2 1 E VG D C ● ● F
Notes:
● Primary Application ○ Secondary Application Good (G)
(1) Not all product capabilities/ limitations are listed. Chart to be used for general Very Good (VG) Excellent (E) Clip Attached (CL) Fontana, CA (F) Tacoma, WA (T)
product selection guidance only. Crimp Curved (CR) Machine Curved (M) Direct Fastened (D) Performance calculated per code provisions (C) Anchorage, AK (A) Sacramento, CA (Sa) Spokane, WA (Sp)
(2) Relative weathertightness rating based on seam height and panel lap design.
(3) In general, most panels may be sprung curved to large radii (inquire for limitations).
(4) All panels are prescriptive within IBC. Compliance reports provided as convenience.
Oil Canning: All flat metal surfaces can display waviness commonly referred to as “oil canning”. “Oil canning” is an inherent
III characteristic of steel products, not a defect, and therefore is not a cause for panel rejection.